Implementation of Bond's scheme in a single crystal diffractometer. Study of the homogeneity of (Y1–xEux)2O3 single crystals Full article
Journal |
Journal of Structural Chemistry
ISSN: 1573-8779 , E-ISSN: 0022-4766 |
||||
---|---|---|---|---|---|
Output data | Year: 2024, Volume: 65, Number: 10, Pages: 1932-1941 Pages count : 10 DOI: 10.1134/S0022476624100056 | ||||
Tags | single crystal X-ray diffraction, unit cell parameters, yttrium oxide, accuracy, reference sample | ||||
Authors |
|
||||
Affiliations |
|
Abstract:
An original procedure is proposed to refine unit cell parameters (UCPs) of single crystals in Bond’s scheme. The procedure involves the use of a modern laboratory diffractometer equipped with a 2D detector and a three-circle goniometer. At the first stage, preliminary UCPs, diffraction class, and crystal orientation relative to goniometer axes are determined. Then ϕ and ω angles are calculated to bring an appropriate (occurrence of a well-resolved doublet, intensity) reflection hkl on the equatorial plane. The measurement in Bond’s scheme is carried out at two symmetric positions of the detector ±2θD ≈ 2θhkl. The principal difference from the measurement on a single crystal spectrometer consists in refusing to plot the reflection profile I(ω) and passing to ω-scans with a width of 3-4°, which allows the measurement of the Kα1/Kα2 doublet profile. After its processing by two independent 2D functions, coordinates of the maxima are determined, and then the 4θhkl. Angle is found based on angular sizes of the detector pixel and the difference in the coordinates of X Kα1-component reflections obtained in symmetric positions. In this approach, measurement errors are related to the accuracy of placing the detector in two symmetric positions and the correctness of processing 2D reflection profiles. In the study of reference Si and Ge single crystals in the range of 2θD angles close to 100°, UCP deviations from the theoretical values are found to not exceed 0.0004 Å, and the relative measurement accuracy is 6⋅10–5. The refinement of UCPs of single crystals grown in the Y2O3–Eu2O3 system by the melt-solution technique indicates the formation of the (Y1–xEux)2O3 solid solution with the x value range of 0.27-0.40. A scheme is proposed to improve the measurement accuracy when the procedure is transferred to the diffractometer with synchrotron radiation.
Cite:
Kudryavtsev A.L.
, Serebrennikova P.S.
, Naumov N.G.
, Gromilov S.A.
Implementation of Bond's scheme in a single crystal diffractometer. Study of the homogeneity of (Y1–xEux)2O3 single crystals
Journal of Structural Chemistry. 2024. V.65. N10. P.1932-1941. DOI: 10.1134/S0022476624100056 WOS Scopus РИНЦ OpenAlex
Implementation of Bond's scheme in a single crystal diffractometer. Study of the homogeneity of (Y1–xEux)2O3 single crystals
Journal of Structural Chemistry. 2024. V.65. N10. P.1932-1941. DOI: 10.1134/S0022476624100056 WOS Scopus РИНЦ OpenAlex
Original:
Кудрявцев А.Л.
, Серебренникова П.С.
, Наумов Н.Г.
, Громилов С.А.
Реализация схемы Бонда на монокристальном дифрактометре. Изучение однородности монокристаллов (Y1-xEux)2O3
Журнал структурной химии. 2024. Т.65. №10. 133158 :1-10. DOI: 10.26902/JSC_id133158 РИНЦ OpenAlex
Реализация схемы Бонда на монокристальном дифрактометре. Изучение однородности монокристаллов (Y1-xEux)2O3
Журнал структурной химии. 2024. Т.65. №10. 133158 :1-10. DOI: 10.26902/JSC_id133158 РИНЦ OpenAlex
Dates:
Submitted: | May 7, 2024 |
Accepted: | May 22, 2024 |
Published print: | Nov 11, 2024 |
Published online: | Nov 11, 2024 |
Identifiers:
Web of science: | WOS:001352837600008 |
Scopus: | 2-s2.0-85209781993 |
Elibrary: | 74529444 |
OpenAlex: | W4404223754 |